{"product_id":"sentry-air-horizontal-laminar-flow-hood","title":"Sentry Air- Horizontal Laminar Flow Hood","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eFor Quotes, simply add desired products to your quote request with the Add to Quote button. You can view your full request at any time by selecting the View Current Quote Request button on the sidebar. If you need assistance please call us at\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e(888) 240-7247\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eor email sa\u003cspan\u003eles@ironforgeindustrial.com\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch6\u003e\u003cstrong\u003eSenty Air Systems Improves Air Quality With High Efficiency Filtration \u0026amp; Versatile Solutions\u003c\/strong\u003e\u003c\/h6\u003e\n\u003cp\u003eHorizontal laminar flow hoods,\u003cspan\u003e \u003c\/span\u003e\u003cem\u003emanufactured by Sentry Air Systems\u003c\/em\u003e, are benchtop workstations that assist in providing a clean workspace by pushing a laminar stream of air through a HEPA filter into the working environment.\u003c\/p\u003e\n\u003cp\u003eThe unique design includes two “wing-style” sides that can adjust to make the work area either wider or more narrow. By utilizing a clear lid, operators have an additional layer of protection from ambient air; as a high-powered fan pulls the ambient air through the HEPA filter chamber - where airborne contaminants are captured then disperses the cleansed air into the work area.\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003eWhat is a Horizontal Laminar Flow Hood?\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003eHorizontal laminar flow hoods are anti-static clean room air filtration systems designed for stationary, benchtop applications requiring an ISO Class 5 rated environment. These flow hoods are unique in functionality as they pull ambient air through a HEPA filter, then disperse the clean air in a laminar flow through the designated work area.\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003eHow does a Horizontal Laminar Flow Hood work?\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ch4\u003e\n\u003cstrong\u003e\u003cimg alt=\"Horizontal Laminar Flow Hood Infographic\" src=\"https:\/\/www.sentryair.com\/images\/Horizontal-Laminar-Flow-Hood-IG.jpg\"\u003e\u003c\/strong\u003e\u003cstrong\u003eHorizontal vs Vertical Laminar Flow Hood\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003eHorizontal Laminar Flow Hoods:\u003cbr\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAmbient air is pulled from the back of the unit by a fan module\u003c\/li\u003e\n\u003cli\u003eThe fan pushes the ambient air through HEPA (or ULPA) rated filters\u003c\/li\u003e\n\u003cli\u003eFiltered clean air is dispersed into enclosed work area of the hood in a horizontal laminar pattern\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eVertical Laminar Flow Hoods (Cleanroom):\u003cbr\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAmbient air is pulled into the filtration system by a fan module\u003c\/li\u003e\n\u003cli\u003e(Air is processed through a MERV 8 pre filter) *SAS Additional Process\u003c\/li\u003e\n\u003cli\u003eThe fan pushes the air through HEPA (or ULPA) rated filers\u003c\/li\u003e\n\u003cli\u003eFiltered air is discharged into the enclosed work area of the hood in a vertical laminar pattern\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003e\n\u003cstrong\u003eIs your application appropriate for a horizontal laminar fume hood?\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003eHorizontal Laminar Flow Hoods are often required for pharmaceutical, medical, food and beverage manufacturing, tissue culture, electronics assembly and any other applications requiring an ISO Class 4 or 5 level of cleanliness. In some circumstances, important considerations must be taken, including what types of powders, chemicals, or biological mutagens will be handled, the quantity, and at what temperature. In these cases, speaking with a subject matter expert to determine whether or not your application requires a horizontal laminar flow hood is advisable.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eBenefits of a SAS Horizontal Laminar Flow Hood\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003eAnti-Static\u003c\/li\u003e\n\u003cli\u003eAdjustable Wing Flaps\u003c\/li\u003e\n\u003cli\u003eHighly Portable and Lightweight\u003c\/li\u003e\n\u003cli\u003eReliable, Quiet, Low Maintenance Operation\u003c\/li\u003e\n\u003cli\u003eSimple, Quick \"No Tool\" Filter Change\u003c\/li\u003e\n\u003cli\u003eSturdy Construction\u003c\/li\u003e\n\u003cli\u003eLong Filter Life\u003c\/li\u003e\n\u003cli\u003eClear Acrylic Lid and Curtains Included\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003e\u003cstrong\u003eBrochures (Specs)\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0659\/3075\/6315\/files\/ss-125-wsl-pp.pdf?v=1756749952\" target=\"_blank\" title=\"Stainless Steel Positive-Pressure Winged Sentry\" rel=\"noopener\"\u003eStainless Steel Positive-Pressure Winged Sentry\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003eHow do Horizontal Laminar Flow Hoods work?\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.sentryair.com\/products\/horizontal-laminar-flow-hood\/images\/horizontal-laminar-flow-features-infographic.jpg\" alt=\"Horizontal Laminar Flow Hood\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sentry Air","offers":[{"title":"Default Title","offer_id":47511263707355,"sku":"SS-125-WSL-PP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0659\/3075\/6315\/files\/ss-100-wsl-pp.jpg?v=1756749742","url":"https:\/\/ironforgeindustrial.com\/products\/sentry-air-horizontal-laminar-flow-hood","provider":"Iron Forge Industrial","version":"1.0","type":"link"}